{"product_id":"heat-aerosol-fire-extinguishing-device-for-din-rail-electrical-panels","title":"Heat Aerosol Fire Extinguishing Device for DIN Rail Electrical Panels","description":"\u003ch3 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eAutomatic Fire Suppression for Your Electrical Systems\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eThe Heat Aerosol Fire Extinguishing Device is a modern fire suppression system developed to combat fires quickly and efficiently in small, confined spaces such as electrical boxes, distribution boards, and server rooms. Unlike traditional fire extinguishers that rely on pressurized gas or foam, this device uses a solid chemical mixture that undergoes an oxidation-reduction reaction when activated.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eHow It Works\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eWhen activated by heat, the device releases a large amount of fire-extinguishing aerosol through a chemical reaction. This aerosol works both physically and chemically to suppress flames and prevent the spread of fire. The metal salt particles generated absorb heat and inhibit combustion. The resulting aerosol remains suspended in the air for an extended period, ensuring that fires are extinguished even in hard-to-reach corners of your electrical enclosures.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eRapid Response\u003c\/strong\u003e The device activates in under 15 seconds at 170°C and discharges within 6 seconds, ensuring fast action in the event of a fire.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003ePower-Independent Operation\u003c\/strong\u003e This device is fully thermal-activated, meaning it does not require electricity to function. This makes it ideal for electrical enclosures where power cuts or electrical issues could otherwise prevent operation of traditional fire suppression systems.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eEnvironmentally Responsible\u003c\/strong\u003e It is non-toxic, non-corrosive, and does not contribute to ozone layer depletion, making it an environmentally responsible choice for fire protection in any setting.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eLong Service Life\u003c\/strong\u003e With a 10-year shelf life, this fire extinguisher requires minimal maintenance, offering long-term peace of mind for users. Simply install and forget—it works silently in the background.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eCompact \u0026amp; Space-Saving Design\u003c\/strong\u003e At only 18mm wide, it is compact enough to fit into tight spaces like electrical cabinets, control panels, and server rooms, where space is often limited. The small footprint means you don't sacrifice valuable enclosure space.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eEasy Installation\u003c\/strong\u003e The device can be easily mounted using a 35mm DIN rail or 3M adhesive, ensuring a simple installation process without requiring significant modifications to existing systems.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eSeamless Integration\u003c\/strong\u003e The device is designed to blend seamlessly with existing electrical systems and circuit protection products, maintaining the aesthetics of the control panel while providing essential fire protection.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003ePerfect Applications\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eThis device is ideal for a range of environments, particularly those with electrical systems and sensitive equipment:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eElectrical Cabinets \u0026amp; Distribution Boards\u003c\/strong\u003e Protect electrical enclosures from fire hazards caused by overheating or electrical malfunctions. Essential for any building's electrical distribution infrastructure.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eControl Panels \u0026amp; Industrial Systems\u003c\/strong\u003e Keep industrial control systems secure from fire damage in tight and hard-to-reach areas. Critical for manufacturing facilities and automation systems.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eSolar Inverter Cabinets\u003c\/strong\u003e Safeguard your solar power system from thermal runaway and electrical fires. Increasingly important as solar installations grow in Pakistan.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eBattery Storage Enclosures\u003c\/strong\u003e Protect battery backup systems and energy storage solutions that can generate excessive heat during charging cycles.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eServer Rooms \u0026amp; Data Centers\u003c\/strong\u003e Safeguard valuable IT equipment and data centers, where fire suppression systems must be effective without risking damage to sensitive electronics.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eTelecom \u0026amp; Network Cabinets\u003c\/strong\u003e Keep communication infrastructure safe from fire hazards in confined equipment spaces.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eSmall Enclosed Electrical Spaces\u003c\/strong\u003e Any confined area housing electrical or electronic equipment that may be prone to fire hazards can benefit from this reliable fire suppression system.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\" class=\"overflow-x-auto w-full px-2 mb-6 print:overflow-x-visible\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeat Aerosol Fire Extinguishing Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eExtinguishing Agent Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eProtected Space Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eUp to 0.1 m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-50°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eActivation Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eApproximately 170°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eService Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eExtinguishing Density\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e100g\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eMaximum Casing Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u0026lt;200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eActivation Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eUnder 15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eDischarge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eWithin 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eCompliance Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEN 15276-1:2019, EN 15276-2:2019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eDesign Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e18mm (compact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eInstallation Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e35mm DIN rail or 3M adhesive mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eManufacturing Date\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMay 2026\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eCE Marked\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eWhy Choose This Fire Extinguishing Device?\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eFast and Effective Fire Suppression\u003c\/strong\u003e The quick activation and discharge of fire-extinguishing aerosol ensure that fires are suppressed before they can cause significant damage to your valuable electrical equipment.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eNon-Intrusive and Compact\u003c\/strong\u003e Its small size and simple installation make it an unobtrusive addition to electrical systems, providing high-performance fire protection without occupying valuable space or requiring extensive modifications.\u003c\/p\u003e","brand":"Mayo.pk","offers":[{"title":"Default Title","offer_id":46180715298850,"sku":null,"price":1500.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1897\/2706\/files\/Heat-Aerosol-Fire-Extinguishing-Device-1-600x600.webp?v=1785754059","url":"https:\/\/mayo.pk\/products\/heat-aerosol-fire-extinguishing-device-for-din-rail-electrical-panels","provider":"Mayo.pk","version":"1.0","type":"link"}